An OTDR measures the time light takes to reach a break and come back, and turns it into a distance along the glass. The cable on the ground is shorter than the fibre inside it, and some of it is coiled in pits, closures and on poles, so the dig spot is nearer than the trace says. This calculator makes those corrections.
The four corrections
- Launch cord: if the trace is measured from the OTDR port and not from the end of the launch cord, take the launch cord length off.
- Index of refraction: the OTDR works out distance from the group index it is set to. If that differs from the fibre's own index (on the cable datasheet, usually about 1.467 to 1.468 at 1310 and 1550 nm), the distance scales by the ratio: set index divided by true index.
- Extra fibre length: in a loose tube cable the fibres lie in a helix, so they are longer than the sheath, often by somewhere around 0.5% to 2%. The datasheet or a test on a known length of the same cable gives the real figure. The sheath metre marks at each end of the route are the best check.
- Slack: coils stored in handholes, at closures and on poles use cable without moving along the route. Add up the slack stored between the OTDR end and the break from the as-built drawings.
Narrow it down before you dig
Test from both ends if you can: two readings that agree on the same point give a far smaller window. Compare the trace with the as-built drawings and the sheath metre marks at the nearest closure or pit, and walk the route for signs of digging, a new post or a fallen pole. The search window here assumes the extra fibre length is within half a percent of the figure you give and the reading within 2 m. See fibre optic cable repairs and OTDRs and test equipment.
Why the trace distance is what it is
Light in glass travels at the speed of light divided by the group index, about 204 000 km per second. The OTDR halves the round trip: distance = speed of light x time / (2 x index). One kilometre of fibre takes about 9.8 µs out and back. A wrong index setting of 0.003 shifts a 10 km reading by about 20 m, which is why the setting matters on long routes.
A guide, not a design
These figures follow the published standards and common design values, and the calculators work in your browser. They are a guide for planning and checking quotes. The datasheets for your cable and optics, and the network designer or contractor, have the final word. Nothing you type here is sent anywhere.