Inside a building, a server room or a data centre hall, the runs are short and there are many of them. That is where multimode fibre earns its place: a wider 50 µm core and cheaper short-reach optics. The grade matters. OM3 and OM4 carry 10 Gb/s across a typical building, while older OM1 and OM2 struggle. This page covers the OM grades and their colours, the distances you can count on, MPO trunks in data centres, when single-mode is the better choice and why you must never mix fibre types in one link.
OM1 to OM5 and their colours
- OM1 (62.5/125) and OM2 (50/125): older grades, usually orange jackets. Found in older buildings.
- OM3 and OM4 (50/125, laser-optimised): aqua jackets, and OM4 is also sold in violet. The usual choice today.
- OM5: lime green, for equipment that uses several wavelengths on one fibre.
All run at 850 nm, and at 1300 nm on some equipment. Multimode loss is much higher than single-mode, about 3 dB per km at 850 nm, which is why it stays inside buildings.
Distances you can plan on
For 10 Gb/s short-reach optics the IEEE figures are about 300 m on OM3 and about 400 m on OM4. Faster speeds reach less far on the same fibre, so check the reach for the exact optic in the maker's datasheet. Connectors and splices also eat into the loss budget, so a link with several patch panels needs more care than a straight run. If the link may go further than a few hundred metres, or between buildings, choose single-mode fibre instead.
Server rooms, data centres and MPO trunks
In a data centre, multimode often arrives as pre-terminated MPO trunks: 8, 12, 16 or 24 fibres in one connector, plugged into cassettes in patch panels that break out to LC ports. Trunks are made to length, so measure carefully: they save termination time and arrive tested, but a trunk cut too short cannot be stretched. Agree the polarity type (A, B or C) with the supplier. In an office, multimode tight buffered cable runs from the server room to floor cabinets as part of network cabling, with aqua patch cords to the switches.
Never mix types in one link
Don't join 50 µm and 62.5 µm fibre, and never join multimode to single-mode. The cores don't match, so much of the light is lost. When you extend an old installation, find out what is there first: the jacket colour helps, the print on the cable confirms it, and an installer can test it. The optics must match too, so multimode SR modules on multimode fibre. If you are upgrading an older OM1 or OM2 backbone, it is often simpler to replace it than to work around its limits.
What to put in your request
- The OM grade you need or already have
- Each run's length, measured or from drawings
- Loose cable or pre-terminated MPO trunks
- The connectors at each end, such as LC
- LSZH or another jacket the building requires
Multimode Fibre Cable for estates, offices, factories, mines, farms and more
- Houses and home offices: a short link to a home office or rack, though single-mode often suits better
- Estates, complexes and body corporates: short links inside a clubhouse or gatehouse comms room
- Offices, business parks and shops: backbones from the server room to floor cabinets and between floors
- Factories, warehouses and plants: links inside a plant building to control room switches
- Mines, quarries and heavy industry: short links inside control rooms, workshops and office blocks
- Farms, wine estates and lodges: rarely used, except inside a packhouse or office building
- Schools, campuses, hospitals and municipalities: backbones inside school blocks, hospital wings and municipal buildings
- Data centres and server rooms: MPO trunks and patching between racks, rows and halls
- Network operators, ISPs and contractors: short patching inside exchanges and hosting suites
Frequently asked questions
Do you install multimode cabling yourselves?
No. We are a free quote request service: we pass your request to independent suppliers and network cabling installers in your area, and they quote you directly. We stock and install nothing.
OM3 or OM4: which should I buy?
OM4 reaches further at the same speed and leaves more room for future equipment, and the price gap is often small. For new work many installers specify OM4. Ask for both prices in your request.
Can I connect new OM4 to an old OM1 backbone?
Not in the same link. OM1 has a 62.5 µm core and OM4 a 50 µm core, and joining them loses light. Replace the old backbone or keep the two systems separate with equipment between them.
Is multimode cheaper than single-mode?
The cable costs about the same; the saving is in the short-reach optics. For a room full of short links that can add up. For a few links between buildings, single-mode is usually the better buy. Ask the installer to price the optics as well as the cable, because that is where the difference shows.
Multimode Fibre Cable by province and city
- Johannesburg
- Pretoria
- Centurion
- Midrand
- Sandton
- Randburg
- Roodepoort
- Krugersdorp
- Randfontein
- Germiston
- Boksburg
- Benoni
- Kempton Park
- Alberton
- Vanderbijlpark
- Vereeniging
- Durban
- Pinetown
- Pietermaritzburg
- Richards Bay
- Newcastle
- Ladysmith
- Gqeberha (Port Elizabeth)
- East London
- Kariega (Uitenhage)
- Mthatha
- Cape Town
- Bellville
- Paarl
- Stellenbosch
- George
- Worcester
- eMalahleni (Witbank)
- Middelburg
- Secunda
- Mbombela (Nelspruit)
- Rustenburg
- Brits
- Klerksdorp
- Potchefstroom
- Mahikeng
- Polokwane
- Tzaneen
- Kimberley
- Upington
- Bloemfontein
- Welkom
- Sasolburg
